AVK Resilient Seated Gate Valve
Clockwise To Close & Clockwise to Open
Mamoun Humayra
Water Product Manager
Resilient seated gate valve to BS EN 1074-2 / BS 5163-1 for water and waste water. Temperature range: -10° C to +70° C. .
The Series 21/60 is a resilient seated, wedge gate valve, rated to PN25, suitable for use with water and neutral liquids, to a maximum temperature of +70°C.
Variant 21/60-001 | |
---|---|
Connection: | Flanged |
Material: | Ductile Iron |
DN: | DN50 - DN300 |
PN: | PN 25 |
Features
- Cap top as standard.
- Ductile iron wedge, fully vulcanised with EPDM rubber.
- O-ring stem seals replaceable under pressure.
- Fusion bonded epoxy coating.
- Fully corrosion resistant construction.
- Body, bonnet and gland bolts sealed with hot-melt.
- Blue fusion bonded epoxy coating in line with WIS 4-52-01
- Components WRAS approved.
- Bosses for sampling or by-passing (undrilled).
- Embodied carbon data available upon request
- Options:
- Clockwise to open (red insert), clockwise to close (white insert)
- Handwheel.
- Electric actuation.
- Alternative flange drilling.
- Bevel or spur gearboxes.
- Full range of flange adaptors and dismantling joints.
Downloads
Installation, Operation & Maintenance
Price list
FAQs
Flyer
Product Brochure
Guidelines
Outline drawings DWG
Outline drawings DXF
Outline drawings IGS
Outline drawings STEP
Related Datasheets
Datasheet
Certificate(s)
Reference nos. and dimensions:
Scroll for more info
Ref. no. | DN mm |
Bolt No. |
Torque Nm |
Running torque Nm |
W mm |
F mm |
H mm |
H3 mm |
L mm |
---|---|---|---|---|---|---|---|---|---|
21-050-60-2740069 | 50 | 4 | 165 | 19 | 279 | 362 | 178 | ||
21-050-60-3740069 | 50 | 4 | 165 | 19 | 279 | 362 | 178 | ||
21-080-60-2740069 | 80 | 8 | 200 | 19 | 294 | 364 | 203 | ||
21-080-60-3740069 | 80 | 8 | 200 | 19 | 294 | 394 | 203 | ||
21-100-60-2740069 | 100 | 8 | 235 | 19 | 324 | 442 | 229 | ||
21-100-60-3740069 | 100 | 8 | 235 | 19 | 324 | 442 | 229 | ||
21-150-60-2740069 | 150 | 8 | 300 | 24 | 429 | 579 | 267 | ||
21-150-60-3740069 | 150 | 8 | 300 | 24 | 429 | 579 | 267 | ||
21-200-60-2740069 | 200 | 12 | 360 | 27 | 531 | 711 | 292 | ||
21-200-60-3740069 | 200 | 12 | 360 | 27 | 531 | 711 | 292 | ||
21-250-60-2740069 | 250 | 12 | 425 | 27 | 614 | 827 | 330 | ||
21-250-60-3740069 | 250 | 12 | 425 | 27 | 614 | 827 | 330 | ||
21-300-60-2740069 | 300 | 16 | 485 | 27 | 690 | 933 | 356 | ||
21-300-60-3740069 | 300 | 16 | 485 | 27 | 690 | 933 | 356 |
Enquiry
Scroll for more info
Components
1. | Stem Cap | Cast iron GJL-250 |
2. | Stem | Stainless steel 1.4021 |
3. | Gland Flange Assembly | Ductile iron |
4. | Thrust collar | Brass CW602N |
5. | Bonnet | Ductile Iron GJS-500-7 |
6. | Bonnet bolt | Steel 8.8 |
7. | Body-bonnet seal | EPDM |
8. | Body | Ductile Iron GJS-500-7 |
9. | Wedge | Ductile iron |
10. | Coating | Epoxy |
Test/Approvals
- Hydraulic test according to EN 1074-1 and 2 / EN 12266.
- Approved according to WRAS
- Drinking Water Inspectorate Regulation 31 compliant
Standards
- Designed according to BS5163/B, Designed according to BS EN 1074 -1 and 2
- Face to face according to EN 558 Table 2 Basic Series 3
- Standard flange drilling to EN1092 (ISO 7005-2), PN 25